Home> Blog> What is the difference between a variable frequency motor and an ordinary motor?

What is the difference between a variable frequency motor and an ordinary motor?

June 01, 2023
Want to know the difference between a variable frequency motor and a normal motor? First of all, to understand what is the inverter? What are the classifications of the inverter? What is the working principle of the inverter?
Want to know the difference between a variable frequency motor and a normal motor? First of all, to understand what is the inverter? What are the classifications of the inverter? What is the working principle of the inverter? Dalan Motor Xiaobian made the following summary.

1, the definition of the inverter

1 Inverter is a device that converts power frequency power supply (50Hz or 60Hz) into AC power of various frequencies to realize variable speed operation of the motor.

2 The control circuit completes the control of the main circuit, the rectifier circuit converts the alternating current into direct current, the direct current intermediate circuit smoothes the output of the rectifier circuit, and the inverter circuit reverses the direct current into alternating current.

3 vector control inverter This kind of inverter that requires a lot of calculations, sometimes requires a CPU for torque calculation and some corresponding circuits.

4 Frequency control is to achieve the purpose of speed regulation by changing the frequency of the motor stator winding power supply.

5 frequency conversion technology was born in response to the need for AC motor stepless speed regulation.

2, the classification of the inverter

1 According to the working mode of the main circuit, it is divided into voltage type inverter and current type inverter;

2 According to the switch mode, it is divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;

3 According to the working principle, it is divided into V/f control inverter, slip frequency control inverter and vector control inverter;

4 According to the use, it is divided into general-purpose inverter, high-performance special inverter, high-Frequency Inverter, single-Phase Inverter and three-phase inverter.

5VVVF: change voltage and change frequency;

6CVCF: constant voltage, constant frequency.

7 Inverter for motor control can change the voltage and change the frequency.

3, the working principle of the inverter

The synchronous speed expression of the AC motor is: n=60f(1-s)/p

Where: n - the speed of the asynchronous motor; f - the frequency of the asynchronous motor; s - the motor slip rate; p - the number of poles of the motor.

It can be known from the above formula:

1 The speed n is proportional to the frequency f, and the speed of the motor can be changed as long as the frequency f is changed;

2 When the frequency f is varied from 0 to 50 Hz, the motor speed adjustment range is very wide.

3 Inverter is to achieve speed adjustment by changing the motor power "target=_blank> machine power frequency, is an ideal high-efficiency, high-performance speed control means.








----- Editor-in-Chief: Dalan Oil Pump Motor 02-Procurement Consultant

Copyright http: / (Dalan Motor) Reprint, please indicate the source
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn
Contact Us

Author:

Mr. andysun

Phone/WhatsApp:

+8615861598173

Popular Products
You may also like
Related Information
Frequency control of water pump variable frequency range of three factors

Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major...

Zhou Heliang: Inverter market will be doubled in 5 years optimistic about the development of variable frequency speed control technology

Affected by the macroeconomic environment, China's inverter market in 2012 is not ideal. According to the company announced 2012 earnings, ABB Group sales in 2012 was about 3.7 billion yuan,...

DYWPX2 variable frequency pump installation requirements are there?

[Asia pump network hearing] variable frequency constant pressure pump installed as required to ensure its normal operation. Next, Xiao Bian and everyone introduced DYWPX2 variable frequency pump...

Frequency control of the variable frequency speed range of the pump three major factors

Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send