The inverter motor runs at no load, and the power and the number of poles of the variable frequency motor are set. The operating current of the inverter should be considered comprehensively.
Set the maximum output frequency, fundamental frequency, and set torque characteristics of the inverter. The general-purpose inverters are equipped with multiple VPf curves for the user to select. The user should select the appropriate VPf curve according to the nature of the load. In the case of fan and pump loads, set the torque running code of the Frequency Converter to variable torque and torque reduction operating characteristics. In order to improve the low-speed performance of the inverter when starting, the torque output from the motor can meet the requirements of the production load start-up, and the starting torque should be adjusted. In the asynchronous motor variable frequency speed control system, the torque control is more complicated. In the low frequency band, since the influence of resistance and leakage reactance cannot be ignored, if the VPf is kept constant, the magnetic flux will decrease, thereby reducing the output torque of the motor. For this reason, the voltage is appropriately compensated at the low frequency band to increase the torque. Generally, the inverter is manually compensated by the user.
Set the inverter to its own keyboard operation mode, press the run key and stop key to observe whether the motor can start and stop normally.
Be familiar with the protection code when the inverter runs fault, observe the factory value of the thermal protection relay, observe the setting value of the overload protection, and modify it if necessary. The user of the inverter can set the electronic thermal relay function of the inverter according to the instruction manual of the inverter. When the output current of the inverter exceeds its allowable current, the overcurrent protection of the inverter will cut off the output of the inverter. Therefore, the maximum threshold of the inverter electronic thermal relay does not exceed the maximum allowable output current of the inverter.

Contact Us

Author:

Mr. andysun

Phone/WhatsApp:

+8615861598173

Popular Products
You may also like
Related Information
Frequency control of water pump variable frequency range of three factors

Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major...

Zhou Heliang: Inverter market will be doubled in 5 years optimistic about the development of variable frequency speed control technology

Affected by the macroeconomic environment, China's inverter market in 2012 is not ideal. According to the company announced 2012 earnings, ABB Group sales in 2012 was about 3.7 billion yuan,...

DYWPX2 variable frequency pump installation requirements are there?

[Asia pump network hearing] variable frequency constant pressure pump installed as required to ensure its normal operation. Next, Xiao Bian and everyone introduced DYWPX2 variable frequency pump...

Frequency control of the variable frequency speed range of the pump three major factors

Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send