Home> Blog> Digital display recorder variable frequency flow can debug pump

Digital display recorder variable frequency flow can debug pump

June 03, 2023
The digital display recorder variable frequency flow can be debugged. The pump has the following functions: The device has the following functions: pressure remote control, automatic boost pressure, automatic pressure compensation, manual gradient boost, remote automatic pressure relief, variable frequency variable flow control and The test process is monitored in real time using computer background software directly.
Digital display recorder variable frequency flow can debug pump

The digital display recorder variable frequency flow adjustable commissioning pump has the following functions:
The device has the following functions: pressure remote control, automatic boost pressure, automatic pressure compensation, manual gradient boost, remote automatic pressure relief, variable frequency variable flow control and real-time monitoring of the test process with computer background software.
Before using the pump, just set the upper and lower limit pressure values ​​on the electric contact pressure gauge, set the time required for holding pressure on the digital display time relay, and then use the remote control or press the test pump start button. During the pressure test, the operator can arbitrarily change the speed of the test pump motor by twisting the inverter knob to achieve the purpose of adjusting the boost flow and boost time of the test pump. When the pressure reaches the target value set by the pressure test, the pressure test pump will automatically stop entering the pressure holding state. When the pressure value drops to the lower limit, the pressure test pump automatically starts the pressure compensation to the upper limit stop. When the pressure is kept to the device, the device will pass the buzzer alarm and then automatically relieve pressure through the high pressure solenoid valve or depressurize through the manual pressure relief valve. During the pressure test, the pump not only displays the pressure value curve in real time, but also has a curve change that automatically records the boost value and the boost pressure holding process, and the digital display recorder will completely print out the boost and pressure holding process. The curve changes. In the test process, the digital recorder pressure acquisition system can display the pressure value and the real-time pressure curve in real time, automatically record the curve value of the boost value and the boost pressure maintaining process, and store and print the historical report.
In addition, the digital display recorder variable frequency flow control system can be directly connected to the computer (notebook) through the data line, and the test status, pressure value and pressure curve can be observed in real time through the computer background software, and the test report can be printed at any time through the computer import data. The test report format electronic file can be edited at any time.


All of our electric test pressure pumps can be converted to diesel motor drives.

Pressure test pump contact information:
Yu Hong Telephone 028-69698027
QQ: 1363796774
Http://news.chinawj.com.cn Digital display recorder variable frequency flow can debug pump Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn Digital display recorder variable frequency flow can debug pump
Contact Us

Author:

Mr. andysun

Phone/WhatsApp:

+8615861598173

Popular Products
You may also like
Related Information
Frequency control of water pump variable frequency range of three factors

Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major...

Zhou Heliang: Inverter market will be doubled in 5 years optimistic about the development of variable frequency speed control technology

Affected by the macroeconomic environment, China's inverter market in 2012 is not ideal. According to the company announced 2012 earnings, ABB Group sales in 2012 was about 3.7 billion yuan,...

DYWPX2 variable frequency pump installation requirements are there?

[Asia pump network hearing] variable frequency constant pressure pump installed as required to ensure its normal operation. Next, Xiao Bian and everyone introduced DYWPX2 variable frequency pump...

Frequency control of the variable frequency speed range of the pump three major factors

Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major...

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send